DATA LOOP RESISTANCE TABLES
FOR THERMOCOUPLE WIRE - OHM/100 ft.
AWG Iron/
Constantan
Copper/
Constantan
Chromel/
Alumel*

SOLID

8 2.145 2.409 3.646
12 5.423 4.661 9.219
14 8.625 7.413 14.66
16 13.71 11.78 23.30
17 17.30 14.87 29.39
18 21.80 18.74 37.07
20 35.69 29.82 58.97
22 55.11 46.91 93.68
24 87.66 75.34 149.0
26 139.4 119.8 237.0

STRANDED

14 7.873 6.767 13.38
16 12.53 10.77 21.29
17 18.52 15.92 31.50
18 19.91 17.11 33.85
20 34.85 29.95 59.25
22 50.28 43.21 85.52

Return To References Home Page

 

 

© 2008 Allen Electric Supply Co.  All rights reserved.  Other websites wishing to link to this website are authorized only to link to our homepage with the provision that our site will not be framed within the other website.  Linking to pages other than our homepage without our written permission is prohibited.  All brand or product names used throughout this website are trademarks of their respective holders.  Published by Allen Electric Supply Co.  Comments or Suggestions:  service@allenelectric.com